Combinatorial Golden Gate Cloning
Combinatorial Golden Gate Cloning generates constructs for combinations of alternative cloning vector and fragment sequences. The tool is non-interactive and automatically determines the overhangs for each combination. Use Golden Gate Cloning for interactive configuration of cut sites and primers.
To run the tool, go to:
Tools | Molecular Biology Tools (
) | Cloning (
)| Restriction Analysis and Cloning (
) | Combinatorial Golden Gate Cloning (
)
Define cloning vector and fragments
In the "Sequences" wizard, define the cloning vector and fragments (figure 24.49).
Figure 24.49: A design with three fragments and 10 alternative sequences for the second fragment.
To define the cloning vector, click the edit (
) icon to open the "Setup cloning vector" dialog (figure 24.50). The cloning vector can be defined as follows:
- Select one or more DNA sequences (
) (
) from the Navigation Area.
- Enter a sequence manually by clicking Add to add a row and entering a Name and Sequence. To remove a manually entered sequence, select it and click Delete.
The Source column contains the name of the individual sequence or sequence list from which the sequence originated, or indicates that the sequence was added manually.
- Use the checkboxes to include or exclude individual sequences.
Figure 24.50: Defining a single sequence as the cloning vector.
To add a fragment, click Add fragment... and define its sequences in the same way as for the cloning vector. Change the order of fragments using the (
) and (
) icons. To change the sequences defined for a fragment, click the edit (
) icon.
Alternatively, use Populate sequences to load the cloning vector and fragments from the Navigation Area in one operation (figure 24.51). The first element is used as the cloning vector, the second as the first fragment, and so on. The resulting setup can be adjusted using the edit (
) icons.
Figure 24.51: Selecting a cloning vector and three fragments from the Navigation Area.
Automatic matching
In the "Automatic matching" wizard, the following options can be configured (figure 24.52):
- Enzymes from database Optional enzymes selected from the restriction enzyme database. Click the add (
) button to select enzymes (see Manage enzymes), and click OK.
- Enzymes from list An optional enzyme list (
) containing the enzyme to use.
- Type IIS enzyme The enzyme to use. When enzymes are specified using either option above, the enzyme can be selected from the available choices. Otherwise, enter the enzyme name directly.
- Reorder and Reverse complement When checked, fragments can be reordered or reverse complemented to increase the number of compatible overhangs from existing recognition sites.
- Design primers When checked, primers are designed if suitable existing recognition sites with compatible overhangs cannot be identified.
Primer design does not support scarless cloning between fragments when primers are designed on both sides of the junction, as the designed overhang will be part of the construct.
- Fragment bases in primer The number of bases from the fragment to include in generated primers.
Figure 24.52: Configuring automatic matching.
Automatic matching is performed independently for each combination. The decision to design primers, reorder fragments, or reverse complement fragments may therefore differ between combinations.
Choose outputs
In the "Result handling" wizard, the following output options are available:
- Create sequences Creates a sequence list (
) containing one construct for each combination.
- Create primers Creates one sequence list (
) for each combination, containing all primers designed for that combination.
- Create report Creates a report containing:
- A summary table with one row for each construct.
Variable sequences identifies the sequence used for each component for which multiple alternatives were selected.
Validation is OK when no validation findings are present and Findings when findings are present. Rows are colored green for OK, blue when findings are present but assembly is still expected to succeed, and yellow when a finding is expected to prevent successful assembly.
Total ligase fidelity contains the product of the ligase fidelities for all junctions, when available.
- For each construct, a table summarizing the cloning design and, when relevant, a table listing validation findings.
- A summary table with one row for each construct.
See Golden Gate Cloning for more details about automatic matching, ligase fidelities, and output contents.
Reusing cloning configurations
Sequence configurations defined previously can be used in subsequent runs.
Configurations can be copied in multiple ways:
- Copy the configuration defined in the "Sequences" wizard using the Copy all button, available under More....
- Copy the configuration used in previous runs of the tool from the History (
) view of the output (figure 24.53).
Figure 24.53: The history of an output from Combinatorial Golden Gate Cloning with the sequence configuration selected, ready to be copied.
Copied configurations can be pasted into a text file for later use, or can be pasted into the "Sequences" wizard using the Paste button, available under More....
