Detect Adventitious Viral Agents
The Detect Adventitious Viral Agents template workflow can be used for detecting viral sequences in short- or long-read DNA or RNA sequencing data. This workflow provides a general framework and can be applied to data generated using a wide range of protocols and library preparation methods.
Several workflow steps may require user-specific configuration, such as trimming of adapters or other non-biological sequences, or adjustment of detection options and filtering criteria.
The workflow includes all necessary steps for processing and analyzing the reads:
- Various statistics summarizing and visualizing the input reads are produced using QC for Sequencing Reads.
- For short-read data, reads are trimmed using Trim Reads.
- Viral agents are detected using Find Best References using Read Mapping.
- Reference and read mapping statistics are generated using QC for Read Mapping.
- For PCR-amplified data, duplicate reads are removed from the mapping using Remove Duplicate Mapped Reads.
- For paired-read data, pairs mapped as broken pairs are removed using Extract Reads to reduce false positive detections.
- Consensus sequences for the detected viruses are generated using Extract Consensus Sequence.
- Detected viruses are classified as potential adventitious viruses, control viruses, or endogenous viruses, as relevant.
- A summary report is created using Create Sample Report.
Launching the workflow
To run this workflow, go to:
Workflows | Template Workflows | Microbial Workflows (
) | Metagenomics (
) | Taxonomic Analysis (
) | Detect Adventitious Viral Agents (
)
See Launching workflows individually and in batches for general information.
Options can be configured in the following dialogs:
- Choose where to run. When connected to a CLC Server via the CLC Workbench, select where the analysis should be run. We recommend running the analysis on a CLC Server when possible.
- Specify workflow path. The following paths can be configured:
- Use host. Select Yes if the sample contains material from a host organism, for example, if the virus was propagated in host cells. Reads are also mapped to the host references, and reads that map better to the host are excluded from the viral reference mapping.
- Use control viruses. Select Yes if known control viruses were included in the sample. Detected control viruses are classified accordingly.
- Reads type. Select Short reads or Long reads.
- PCR-amplified data. Select Yes if PCR amplification was used when preparing the sequencing library.
- Select Reads. Select the input reads. When analyzing more than one sample at a time, check Batch in the lower left corner of the dialog.
- Select Virus References. Select the virus references used for detection.
We recommend C-RVDB obtained using Download Curated Microbial Reference Database and filtered to retain only complete sequences, i.e. sequences for which "Completeness" is set to "Complete".
- Select Host References. If using a host, select reference sequences for the host or background material in the sample.
- Select Control Virus References. If using control viruses, select the reference sequences for the control viruses included in the sample.
The WHO Control Virus References are available from Download Curated Microbial Reference Database.
- Configure batching, if running the workflow in batch mode. Define the batch units.
- Batch overview, if running the workflow in batch mode. Verify that the batching is as intended.
- Trim Reads, if using short reads. Configure how the reads should be trimmed. If the reads contain known non-biological sequences, such as adapters, ensure that these sequences are removed during this step.
- Find Best References using Read Mapping. Configure the thresholds used for the initial refinement of detected viruses.
- Filter Virus References. Configure the criteria used to evaluate the refined read mapping support for each detected virus after optional duplicate removal and removal of paired reads mapped as broken pairs.
- Create Sample Report. Select relevant summary items and configure thresholds for quality control. These are included in the summary section of the sample report. The default values are appropriate for most data sets, but may need to be adjusted.
- Result handling. Choose if a workflow result metadata and/or log should be saved.
- Save location for new elements. Choose where to save the data, and press Finish to start the analysis.
Output from the Detect Adventitious Viral Agents workflow
The following outputs are generated:
- Detected Targets Reads Track (
): A reads track containing the final mapped reads after optional duplicate removal and removal of paired reads mapped as broken pairs. The track contains reads mapped to the detected viruses represented in both Passed Target References and Failed Target References.
- Passed Target References (
): A table containing the detected viruses that passed Filter Virus References. It includes mapping statistics and additional information about each reference. The table is linked to the Detected Targets Reads Track.
- Sample report (
): Sample report containing essential information from all reports produced by the workflow.The report presents detected viruses in three categories: potential adventitious viruses, control viruses, and endogenous viruses, as relevant.
- QC & Reports folder:
- QC report (
): Summarizes and visualizes various statistics of the input reads.
- Trim reads report (
): Summarizes the performed read trimming.
- Find best references report (
): Summarizes the detection and refinement of viruses.
- Duplicates report (
): Contains information about removal of duplicate mapped reads.
- Consensus Report (
): Summarizes the consensus sequences generated for the detected viruses.
- Coverage report (
): Summarizes reference and read mapping statistics.
- QC report (
- Supplemental folder:
- Host Reads Track (
), if using a host: A reads track containing reads assigned to the host references by Find Best References using Read Mapping.
- Discarded Target References (
): A table containing the viruses discarded during the initial refinement of detected viruses.
- Detected Target Consensus Sequences (
): A sequence list containing consensus sequences generated for the detected viruses.
- Failed Target References (
): A table containing the detected viruses that failed Filter Virus References.
- Host Reads Track (