Analyze Whole Genome Sequencing Data
The Analyze Whole Genome Sequencing Data template workflow can be used for analyzing whole genome sequencing (WGS) DNA data and detecting somatic or germline variants. This workflow provides a general framework for WGS analysis that can be applied to data from a wide range of experimental protocols.
Several workflow steps may require user-specific configuration, such as trimming of adapters or other non-biological sequences, adjustment of variant detection options and filtering criteria.
The workflow includes all necessary steps for processing and analyzing the DNA reads:
- Various statistics summarizing and visualizing the input reads are produced using QC for Sequencing Reads.
- Reads are trimmed using Trim Reads.
- Reads are mapped to the reference genome using Map Reads to Reference.
- Duplicate reads are removed from the mapping using Remove Duplicate Mapped Reads.
- A guidance track is generated from the mapped reads using Structural Variant Caller.
- An improved mapping is obtained by realigning the mapped reads using the guidance track and Local Realignment.
- Reference and read mapping statistics are generated using QC for Read Mapping.
- Variants are detected from the improved mapping using Low Frequency Variant Detection for somatic variants or Fixed Ploidy Variant Detection for germline variants.
- The variants are annotated with various information, such as overlap with repeat/homopolymer regions and genes, and are subsequently filtered to remove likely artifacts using Filter on Custom Criteria.
- Optionally, likely germline variants from 1000 Genomes Project and dbSNP Common are filtered using Filter Known Variants.
- A summary report is created using Create Sample Report.
Launching the workflow
To run this workflow, go to:
Workflows | Template Workflows | Biomedical Workflows (
) | DNA Workflows (
) | Analyze Whole Genome Sequencing Data (
)
See Launching workflows individually and in batches for general information.
Options can be configured in the following dialogs:
- Choose where to run. When connected to a CLC Server via the CLC Workbench, select where the analysis should be run. We recommend running the analysis on a CLC Server when possible.
- Specify workflow path. The following path can be configured:
- Variants of interest. Choose to detect somatic or germline variants.
- Annotate variants. Optionally annotate variants with information about overlaps with external databases (PhastCons conservation scores, ClinVar, dbSNP Commons, 1000 Genomes).
- Filter germline variants. If detecting somatic variants: filter out germline variants (1000 Genomes, dbSNP Commons).
- Select DNA Reads. Select the input reads. When analyzing more than one sample at a time, check Batch in the lower left corner of the dialog.
- Specify reference data handling. Select the relevant Reference Data Set. This specifies the reference genome and other reference resources used in the analysis. See Reference data management for details.
The reference data sets available may depend on the workflow path. Limiting the selected paths may allow more data sets (e.g., mouse and rat).
- Configure batching, if running the workflow in batch mode. Define the batch units.
- Batch overview, if running the workflow in batch mode. Verify that the batching is as intended.
- Trim Reads. Configure how the reads should be trimmed. If the reads contain known non-biological sequences, such as adapters, ensure that these sequences are removed during this step.
- Map Reads to Reference. Configure masking. When using the hg38 human reference genome, regions defined by the Genome Reference Consortium are excluded by default to remove false duplications, including one involving U2AF1.
- Detect Somatic Small Variants or Detect Germline Small Variants. Configure the variant detection options. If variants should be detected at lower frequencies, adjust the Minimum frequency (%) as needed. Note that the value should be no more than half of the frequency specified when filtering variants.
- Filter Somatic Small Variants or Filter Germline Small Variants. Configure how variants should be filtered. The default options are suitable for samples with relatively high quality and coverage providing a strong balance between sensitivity and precision. For lower-quality or lower-coverage samples, when seeking a different sensitivity-precision balance, or for detecting low-frequency variants, additional filters or adjusted thresholds might be needed. See Filter on Custom Criteria for details on how to configure the options.
- Filter Structural Variants. Configure how the structural variants should be filtered. See Filter on Custom Criteria for details on how to configure the options.
- Create Sample Report. Select relevant summary items and configure thresholds for quality control. These are included in the summary section of the sample report. The default values are appropriate for most data sets, but may need to be adjusted.
- Result handling. Choose if a workflow result metadata and/or log should be saved.
- Save location for new elements. Choose where to save the data, and press Finish to start the analysis.
Subsections