Analyze Targeted Sequencing Data
The Analyze Targeted Sequencing Data template workflow can be used for analyzing targeted DNA sequencing data and detecting somatic or germline variants. This workflow provides a general framework for targeted sequencing analysis, including e.g. whole exome sequencing (WES) and targeted amplicon sequencing (TAS), and can be applied to data generated using a wide range of enrichment strategies, including hybrid capture and amplicon-based approaches, with or without unique molecular identifiers (UMIs).
Several workflow steps may require user-specific configuration, such as UMI handling, trimming of adapters or other non-biological sequences, specification of target regions and primers, adjustment of variant detection options and filtering criteria.
The workflow includes all necessary steps for processing and analyzing the DNA reads:
- Various statistics summarizing and visualizing the input reads are produced using QC for Sequencing Reads.
- For data with UMIs, UMIs are removed using Remove and Annotate with Unique Molecular Index.
- Reads are trimmed using Trim Reads.
- Reads are mapped to the reference genome using Map Reads to Reference.
- For data with UMIs, UMI reads are created using Calculate Unique Molecular Index Groups and Create UMI Reads from Grouped Reads.
- For hybrid capture data without UMIs, duplicate reads are removed from the mapping using Remove Duplicate Mapped Reads
- For amplicon data, primers are trimmed from the mapping using Trim Primers of Mapped Reads for single-sided primer data and Trim Primers and their Dimers from Mapping for dual primer data.
- A guidance track is generated from the mapped reads using Structural Variant Caller.
- An improved mapping is obtained by realigning the mapped reads using the guidance track and Local Realignment.
- Target coverage statistics are generated using QC for Targeted Sequencing.
- Variants are detected from the improved mapping using Low Frequency Variant Detection for somatic variants or Fixed Ploidy Variant Detection for germline variants.
- The variants are annotated with various information, such as overlap with repeat/homopolymer regions and genes, and are subsequently filtered to remove likely artifacts using Filter on Custom Criteria.
- Optionally, likely germline variants from 1000 Genomes Project and dbSNP Common are filtered using Filter Known Variants.
- A summary report is created using Create Sample Report.
Launching the workflow
To run this workflow, go to:
Workflows | Template Workflows | Biomedical Workflows (
) | DNA Workflows (
) | Analyze Targeted Sequencing Data (
)
See Launching workflows individually and in batches for general information.
Options can be configured in the following dialogs:
- Choose where to run. When connected to a CLC Server via the CLC Workbench, select where the analysis should be run. We recommend running the analysis on a CLC Server when possible.
- Specify workflow path. The following paths can be configured:
- Data containing UMIs. Choose whether the data contains UMIs or not.
- Library type. Choose which approach was used for target enrichment:
- Capture (probes)
- Amplicon (dual primers)
- Amplicon (single-sided primers)
- Variants of interest. Choose to detect somatic or germline variants.
- Annotate variants. Optionally annotate variants with information about overlaps with external databases (PhastCons conservation scores, ClinVar, dbSNP Commons, 1000 Genomes).
- Filter germline variants. If detecting somatic variants: filter out germline variants (1000 Genomes, dbSNP Commons).
- Select DNA Reads. Select the input reads. When analyzing more than one sample at a time, check Batch in the lower left corner of the dialog.
- Target regions. Choose the relevant target regions.
- Target primers, if analyzing amplicon data. Choose the relevant target primers.
- Specify reference data handling. Select the relevant Reference Data Set. This specifies the reference genome and other reference resources used in the analysis. See Reference data management for details.
The reference data sets available may depend on the workflow path. Limiting the selected paths may allow more data sets (e.g., mouse and rat).
- Configure batching, if running the workflow in batch mode. Define the batch units.
- Batch overview, if running the workflow in batch mode. Verify that the batching is as intended.
- Remove and Annotate with Unique Molecular Index, if analyzing data with UMIs. Specify the read structure, the number of bases to remove, and the length and start position of the UMIs.
- Trim Reads. Configure how the reads should be trimmed. If the reads contain known non-biological sequences, such as adapters, ensure that these sequences are removed during this step.
- Map Reads to Reference. Configure masking. When using the hg38 human reference genome, regions defined by the Genome Reference Consortium are excluded by default to remove false duplications, including one involving U2AF1.
- Remove Ligation Artifacts, if analyzing data with UMIs. Choose whether ligation artifacts should be removed.
- Trim Primers and their Dimers from Mapping, if analyzing amplicon data with dual target enrichment primers. Configure how to trim the primers from the read mapping.
- Trim Primers of Mapped Reads, if analyzing amplicon data with single-sided target enrichment primers. Configure how to trim the primers from the read mapping.
- QC for Targeted Sequencing (somatic) or QC for Targeted Sequencing (germline). Configure the minimum coverage and the coverage levels to report on, as desired.
- Detect Somatic Small Variants or Detect Germline Small Variants. Configure the variant detection options. If variants should be detected at lower frequencies, adjust the Minimum frequency (%) as needed. Note that the value should be no more than half of the frequency specified when filtering variants.
- Filter Somatic Small Variants or Filter Germline Small Variants. Configure how variants should be filtered. The default options are suitable for samples with relatively high quality and coverage providing a strong balance between sensitivity and precision. For lower-quality or lower-coverage samples, when seeking a different sensitivity-precision balance, or for detecting low-frequency variants, additional filters or adjusted thresholds might be needed. See Filter on Custom Criteria for details on how to configure the options.
- Filter Structural Variants. Configure how the structural variants should be filtered. See Filter on Custom Criteria for details on how to configure the options.
- Create Sample Report. Select relevant summary items and configure thresholds for quality control. These are included in the summary section of the sample report. The default values are appropriate for most data sets, but may need to be adjusted.
- Result handling. Choose if a workflow result metadata and/or log should be saved.
- Save location for new elements. Choose where to save the data, and press Finish to start the analysis.
Subsections