Analyze Whole Transcriptome Sequencing Data
The Analyze Whole Transcriptome Sequencing Data template workflow can be used for analyzing RNA expression in whole transcriptome sequencing (WTS) data and can optionally be used to detect fusion genes and RNA variants. This workflow provides a general framework for transcriptome analysis that can be applied to data generated using a wide range of RNA sequencing protocols and library preparation methods.
Several workflow steps may require user-specific configuration, such as trimming of adapters or other non-biological sequences, specification of library type and strand specificity, adjustment of variant detection options and filtering criteria, and configuration of fusion detection.
The workflow includes all necessary steps for processing and analyzing the RNA reads:
- Various statistics summarizing and visualizing the input reads are produced using QC for Sequencing Reads.
- Reads are trimmed using Trim Reads.
- Expression is quantified using RNA-Seq Analysis.
- Optionally, fusions are detected using Detect and Refine Fusion Genes.
- Optionally, RNA variants are detected using Low Frequency Variant Detection for somatic variants or Fixed Ploidy Variant Detection for germline variants.
- The variants are annotated with various information, such as overlap with repeat/homopolymer regions and genes, and are subsequently filtered to remove likely artifacts using Filter on Custom Criteria.
- A summary report is created using Create Sample Report.
Launching the workflow
To run this workflow, go to:
Workflows | Template Workflows | Biomedical Workflows (
) | RNA Workflows (
) | Analyze Whole Transcriptome Sequencing Data (
)
See Launching workflows individually and in batches for general information.
Options can be configured in the following dialogs:
- Choose where to run. When connected to a CLC Server via the CLC Workbench, select where the analysis should be run. We recommend running the analysis on a CLC Server when possible.
- Specify workflow path. The following paths can be configured:
- Detect RNA variants. Skipping this may reduce workflow execution time.
- Variants of interest. Choose to detect somatic or germline variants.
- Detect fusions. Skipping this may reduce workflow execution time.
- Annotate variants. Optionally annotate variants with information about overlaps with external databases (PhastCons conservation scores, ClinVar, dbSNP Commons, 1000 Genomes).
- Filter germline variants. If detecting somatic variants: filter out germline variants (1000 Genomes, dbSNP Commons).
- Select RNA Reads. Select the input reads. When analyzing more than one sample at a time, check Batch in the lower left corner of the dialog.
- Specify reference data handling. Select the relevant Reference Data Set. This specifies the reference genome and other reference resources used in the analysis. See Reference data management for details.
The reference data sets available may depend on the workflow path. Limiting the selected paths may allow more data sets (e.g., mouse and rat).
- Configure batching, if running the workflow in batch mode. Define the batch units.
- Batch overview, if running the workflow in batch mode. Verify that the batching is as intended.
- Trim Reads (Remove Adapters), Trim Reads (Homopolymers), and Trim Reads (Quality Trim). Configure how the reads should be trimmed. If the reads contain known non-biological sequences, such as adapters, ensure that these sequences are removed during this step.
- RNA-Seq Analysis. Configure strand specificity and library type to match the library used to generate the data. Optionally, choose whether the RNA-Seq analysis should report total counts or another expression measure.
- Detect Somatic Small Variants or Detect Germline Small Variants, if detecting variants. Configure the variant detection options. If variants should be detected at lower frequencies, adjust the Minimum frequency (%) as needed. Note that the value should be no more than half of the frequency specified when filtering variants.
- Filter Somatic Small Variants or Filter Germline Small Variants, if detecting variants. Configure how variants should be filtered. The default options are suitable for samples with relatively high quality and coverage providing a strong balance between sensitivity and precision. For lower-quality or lower-coverage samples, when seeking a different sensitivity-precision balance, or for detecting low-frequency variants, additional filters or adjusted thresholds might be needed. See Filter on Custom Criteria for details on how to configure the options.
- Detect and Refine Fusion Genes, if detecting fusions. Configure the fusion detection options as needed.
- Create Sample Report. Select relevant summary items and configure thresholds for quality control. These are included in the summary section of the sample report. The default values are appropriate for most data sets, but may need to be adjusted.
- Result handling. Choose if a workflow result metadata and/or log should be saved.
- Save location for new elements. Choose where to save the data, and press Finish to start the analysis.
Subsections