QC for Targeted Sequencing

This tool is designed to report the performance (enrichment and specificity) of a targeted re-sequencing experiment. Targeted re-sequencing is due to its low costs, very popular and several companies provide platforms and protocols (learn more at http://en.wikipedia.org/wiki/Exome_sequencing#Target-enrichment_strategies). Array-based approaches are offered by Agilent (SureSelect) and Roche Nimblegen. Furthermore, amplicon sequencing with PCR primers is offered by RainDance, Fluidigm and others.

Given an annotation track with the target regions (for example imported from a bed file), this tool will investigate a read mapping to determine whether the targeted regions have been appropriately covered by sequencing reads. It will also give information about how specific the reads map to the targeted regions. The results are provided both as a summary report and as track or table with detailed information about each targeted region.

Note! This tool is for re-sequencing data only; if you have RNA-seq data, please see RNA-Seq Analysis.

To create the target regions statistics:

        Toolbox | Quality Control (Image quality_control_closed_16_h_p) | QC for Targeted Sequencing (Image QC_target_sequencing_16_n_p)

This opens a wizard where you can select mapping results (Image contig)/ (Image multicontig)/ (Image read_track_16_n_p) as seen in figure 26.1.

Image targeted_step1
Figure 26.1: Select a read mapping.

Clicking Next will take you to the wizard shown in figure 26.2.

Image targeted_step2
Figure 26.2: Specifying the track of target regions.

Click the Browse (Image browse) icon to select an annotation track that defines the targeted regions of your reference genome. You can either import the target regions as an annotation file or convert from annotations on a reference genome that is already stored in the Navigation Area.

The Report type allows you to select different sets of predefined coverage thresholds to use for reporting (see below). Furthermore, you will be asked to provide a Minimum coverage threshold, i.e., the minimum coverage needed on all positions in a target, in order for that target to be considered covered.

Finally, you are asked to specify whether you want to Ignore non-specific matches and Ignore broken pairs. When these are applied reads that are non-specifically mapped or belong to broken pairs will be ignored.

Click Next to specify the type of output you want (see figure 26.3).

Image targeted_step3
Figure 26.3: Specifying how the result should be reported.

There are three options:

Click Finish to create the selected reports.



Subsections