QIAseq Fastq to Annotated Somatic Variants

The QIAseq Fastq to Annotated Somatic Variants template workflow identifies somatic variants from QIAseq Targeted DNA data and annotates these with exon number and amino acid changes. The workflow also produces a read mapping and a coverage report, and if provided with a baseline, copy number variation is also calculated.

The workflow can be found at:

        Template Workflows | LightSpeed Workflows (Image lightspeed_wf_folder_open_16_n_p) | QIAseq workflows (Image qia_ls_folder_open_16_n_p) | QIAseq Targeted DNA (Image qia_ls_target_folder_open_16_n_p) | QIAseq Fastq to Annotated Somatic Variants (Image qia_ls_wf_16_n_p)

If you are connected to a CLC Server via your Workbench, you will be asked where you would like to run the analysis. We recommend that you run the analysis on a CLC Server when possible.

In the first wizard step, select a Reference Data Set (figure 5.8).

This workflow has been set up to process data generated with QIAseq Targeted DNA panels, and it is important to choose the right reference data to get the reads correctly processed.

The off-the-shelf QIAseq Targeted DNA panels are available in the QIAseq DNA Panels hg19 reference data set. If you have not downloaded the Reference Data Set yet, the dialog will offer the opportunity to download it using the Download to Workbench button.

If the QIAseq DNA Panels hg19 reference data set does not contain the needed primers and target regions, a custom reference data set can be created, see http://resources.qiagenbioinformatics.com/manuals/clcgenomicsworkbench/current/index.php?manual=Custom_Sets.html.

Reference data sets for QIAseq Targeted DNA Pro and QIAseq Targeted DNA Ultra panels should not be used with this workflow. The differences in read structure will for example prevent primers from being correctly trimmed.

Image lis_workflow_qia_somatic_step1
Figure 5.8: Select a reference data set.

In the LightSpeed Fastq to Somatic Variants wizard step (figure 5.9) you have the following options:

Image lis_workflow_qia_somatic_step2
Figure 5.9: Select fastq files.

In the next dialog (figure 5.10), specify the relevant target regions from the drop down list.

Image lis_workflow_qia_somatic_step3
Figure 5.10: Select target regions.

Repeat the selection of the appropriate track for target primers in the subsequent dialog (figure 5.11).

Image lis_workflow_qia_somatic_step4
Figure 5.11: Select target primers.

In the QC for Target Sequencing wizard step, define the threshold for minimum coverage (figure 5.12). This threshold is important because it is used in the quality control section of the sample report. In the later wizard step for Create Sample Report, you will be able to adjust the percent bases in the target regions that should meet this threshold.

Image lis_workflow_qia_somatic_step5
Figure 5.12: Set the coverage threshold. This threshold is used in the quality control section of the sample report.

The dialog for Copy Number Variant Detection allows you to specify a control mapping against which the coverage pattern in your sample will be compared in order to call CNVs (figure 5.13). If you do not specify a control mapping, or if the target regions files contains fewer than 50 regions, the Copy Number Variation analysis will not be carried out.

Image lis_workflow_qia_somatic_step6
Figure 5.13: Select control coverage tables or read mappings for copy number variant detection.

Please note that if you want the copy number variation analysis to be done, it is important that the control mapping supplied is a meaningful control for the sample being analyzed. Mapping of control samples for the CNV analysis can be done using the workflow described in QIAseq Fastq to Germline CNV Control.

A meaningful control must satisfy two conditions: (1) It must have a copy number status that it is meaningful for you to compare your sample against. For panels with targets on the X and Y chromosomes, the control and sample should be matched for gender. (2) The control read mapping must result from the same type of processing that will be applied to the sample. One way to achieve this is to process the control using the workflow (without providing a control mapping for the CNV detection component) and then to use the resulting UMI reads track as the control in subsequent workflow runs.

In the Create Sample Report wizard step, select relevant summary items and specify thresholds for quality control (figure 5.14). Summary items, thresholds and an indication of whether specified thresholds were met, will be shown in the quality control section of the sample report. The default summary items are appropriate for many data sets, but may need to be adjusted.

To add more summary items, press Add..., choose the report type LightSpeed fastq to somatic variants or QC for targeted sequencing and select summary items as appropriate.

Image lis_workflow_qia_somatic_create_sample_report
Figure 5.14: Specify summary items. These will be shown in the quality control section of the sample report.

In the final wizard step, choose to Save the results of the workflow and specify a location in the Navigation Area before clicking Finish.



Subsections