Running the Transcription Factor ChIP-Seq tool
To run the Transcription Factor ChIP-Seq tool:
Toolbox | Epigenomics Analysis () | Transcription Factor ChIP-Seq ()
This will open up the wizard shown in figure 29.5 where you can select the input data (the mapped ChIP-Seq reads). Multiple inputs (e.g. replicate experiments) are accepted, provided that they refer to the same genome. Track based read mappings () and stand-alone read mappings () / () are both accepted.
Figure 29.5: Select the input data for the Transcription Factor ChIP-Seq tool.
Click on the button labeled Next to go to the next wizard step (shown in figure 29.6).
Figure 29.6: Options for the Transcription Factor ChIP-Seq tool.
In this wizard step you have the following options:
- Control data The control data, typically a ChIP-Seq sample where the immunoprecipitation step is omitted, can be specified in this option.
- Maximum P-value for peak calling The threshold for reporting peaks can be specified by this option.
Click on the button labeled Next to go to the wizard step shown in figure 29.7.
Figure 29.7: Output options for the Transcription Factor ChIP-Seq tool.
In addition to the annotation track with Peak annotations () that will always be generated by the algorithm, you can choose to select additional output types.
The options are:
- QC report () Generates a quality control report that allows you to check the quality of the reads. The QC report contains metrics about the quality of the ChIP-Seq experiment. It lists the number of mapped reads, the normalized strand coefficient, and the relative strand correlation for each mapping. For each metric, the Status column will be OK if the experiment has good quality or Low if the metric is not as high as expected. Furthermore, the QC report will show the mean read length, the inferred fragment length, and the window size that the algorithm would need to be able to model the signal shape. In case the input contains paired-end reads, the report will also contain the empirical fragment length distribution. The metrics and their definitions are described in more detail in Quality Control of ChIP-Seq data.
- Peak shape filter () The peak shape filter contains the Hotelling Observer filter that was learned by the Transcription Factor ChIP-Seq algorithm. For the definition of Peak shape, see Applying peak shape filters to call peaks.
- Peak shape score () A graph track containing the peak shape score. The track shows the peak shape score for each genomic position. To save disk space, only peak shape scores greater than zero are reported. For the definition of peak shape score, see Applying peak shape filters to call peaks.
Choose whether you want to open the results directly, or save the results in the Navigation Area. If you choose to save the results, you will be asked to specify where you would like to save them.
Subsections