Identify QIAseq Exome Causal Inherited Variants in Trio
The Identify QIAseq Exome Causal Inherited Variants in Trio template workflow identifies putative disease causing, inherited variants in a family of three, where there is an affected parent, unaffected parent and a proband. It does this by creating a list of variants present in both affected individuals and subtracting all variants in the unaffected individual. Additional checks are then carried out, allowing variants to be classified, for example as de novo variants, recessive variants, etc.
The Identify QIAseq Exome Causal Inherited Variants in Trio template workflow can be found at:
Template Workflows | Biomedical Workflows () | QIAseq Sample Analysis () | QIAseq Analysis workflows () | Identify QIAseq Exome Causal Inherited Variants in Trio ()
This workflow can also be launched from the Analyze QIAseq Samples guide, which is described in The Analyze QIAseq Samples guide. It is available under the Exome tab.
If you are connected to a CLC Server via your Workbench, you will be asked where you would like to run the analysis. We recommend that you run the analysis on a CLC Server when possible.
Separate dialog steps are presented for providing the sample data for the proband, the affected parent and the unaffected parent. The names of the steps in the left hand side of the wizard indicate the data that should be entered in that step. For example, sequencing reads for the proband would be selected in the step shown in figure 13.7.
Figure 13.7: The sequence reads for the proband are specified at the "Select reads from proband" wizard step.
The following dialog helps you set up the relevant Reference Data Set. If you have not downloaded the Reference Data Set yet, the dialog will suggest the relevant data set and offer the opportunity to download it using the Download to Workbench button. (See figure 13.8).
Figure 13.8: The relevant Reference Data Set is highlighted. In the text to the right, the types of reference needed by the workflow are listed.
Note that if you wish to Cancel or Resume the Download, you can close the template workflow and open the Reference Data Manager where the Cancel, Pause and Resume buttons are available.
If the Reference Data Set was previously downloaded, the option "Use the default reference data" is available and will ensure the relevant data set is used. You can always check the "Select a reference set to use" option to be able to specify another Reference Data Set than the one suggested.
Separate dialog steps are presented for configuring Fixed Ploidy Variant Detection for analysis of the proband, the affected parent and the unaffected parent samples. The names of the steps in the left hand side of the wizard, and near the top of each dialog, indicate which sample the parameters apply to. For example, step 9 of the wizard shown in figure 13.8 includes the word "proband". This wizard step, displayed in figure 13.9, has the word "proband" in the title near the top of the dialog.
Figure 13.9: Configuration of Fixed Ploidy Variant Detection tool for the proband sample analysis. This tool is configured separately for the anlaysis of each family member.
The Fixed Ploidy Variant Detection settings:
- Minimum coverage: Only variants in regions covered by at least this many reads are called.
- Minimum count: Only variants that are present in at least this many reads are called.
- Minimum frequency: Only variants that are present at least at the specified frequency (calculated as 'count'/'coverage') are called.
In the next two wizard steps, individual filtering settings can be specified for SNVs and Indels for the proband.
In the final wizard step, choose to Save the results of the workflow and specify a location in the Navigation Area before clicking Finish.
Subsections