Detect MSI Status with Baseline Creation template workflow

The Detect MSI Status with Baseline Creation template workflow is designed to support the QIAseq MSI booster panel, SDHS-10101-11981Z. It can be used with either the hg19 or hg38 reference genomes.

To run the workflow, go to:

        Template Workflows | Biomedical Workflows (Image biomedical_twf_folder_open_16_n_p) | QIAseq Sample Analysis (Image qiaseqrna_folder_closed_16_n_p) | QIAseq Analysis Workflows (Image qiaseq_workflows_folder_closed_16_n_p) | Detect MSI Status with Baseline Creation (Image qiaseq_msi_status_16_h_p)

In the first dialog select the reads for analysis (figure 6.39).

Image msicreatebaselineselectreads
Figure 6.39: Select the sequencing reads by double-clicking on the file name or by clicking once on the file name and then on the arrow pointing to the right hand side.

In the next dialog, select the UMI read mappings of the MSS samples forming the Loci Baseline (figure 6.40). Baseline mappings should be created from at least 15 MSS FFPE samples, preferably samples analyzed on the same sequencing instrument. Ideally, the samples would be from normal biopsies matched with the tumor samples being analyzed. By including the normal sample in the analysis, bias can be avoided.

Image msicreatebaselineselectbaseline
Figure 6.40: Select at least 15 MSS samples to form a baseline.

If you already have read mappings for the MSS samples, these can be used as input to this workflow. You may have such mappings if the MSS samples have been analyzed together with data from other QIAseq custom panels or from a QIAseq Targeted DNA panel.

If you do not already have read mappings for the MSS samples then these can be generated using an edited copy of the Detect MSI Status with Baseline Creation workflow. Modify a copy of this workflow by right clicking on the workflow in the Toolbox and selecting the menu option "Open Copy of Workflow". Delete the MSI tools Detect MSI Status and Generate MSI Baseline from the workflow, save it, and then run it. Provide the MSS samples as input. The output read mappings from this workflow run can then be used as inputs to the original Detect MSI Status with Baseline Creation workflow.

In the next dialog, choose either the QIAseq TMB Panels hg38 (no alternative analysis set) or a custom reference data set based on QIAseq DNA Panel hg19. Note that your reference data must match the reference sequence used for your MSS UMI read mappings.

To create a reference data set based on QIAseq DNA Panel hg19, first download the MSI Loci Track in hg19 coordinates. This is available as a Reference Data Element that can be found under the "QIAGEN Sets" tab of the Reference Data Manager. Then create a Custom Reference Data Set to match this workflow as described here http://resources.qiagenbioinformatics.com/manuals/clcgenomicsworkbench/current/index.php?manual=Custom_Sets.html.

In the Configure batching and Batch overview wizard steps use the default settings. The MSI Loci Track step can be configured to use either the 9 loci or the 27 loci version of the loci (figure 6.40), or a custom selection if this has been created beforehand (for more on how to create a custom selection of loci see Detect MSI Status).

Image msicreatebaselinelociselection
Figure 6.41: Select an MSI loci track.

Select settings for Result handling and a Save location for new elements and press Finish to start the analysis.